MegaPhase 75-ohm test cables offer ideal alternative to expensive OEM cables employed in bench-top testing of CATV products. A selection of precision 75-ohm connectors compliment the line. These test cables are designed to survive in rugged test environments and provide stable performance under flexure enabling repeatable measurements between calibrations. The cables are available in phase matched sets and can be color coded to reduce interconnect confusion.

Electrical Data
Maximum Frequency: 8 GHz

Impedence: 75 Ω nominal

Propagation Velocity: 66% nominal

Time Delay: 1.54 ns/ft (5.05 ns/m)

Shielding Effectiveness:
-110 dB minimum (cable only)

Dielectric Withstanding Voltage:
3 kV at 60 Hz

Capacitance: 20.5 pF/ft (67.3 pF/m)

Mechanical Data
Finished Outer Diameter:
0.285 in (0.724 cm)

Static Bend Radius: 0.5 in (1.27 cm)

Weight with Standard Jacket/Armor:
0.05 lbs/ft (0.067 kg/m)

Crush Resistance:
250 lbs/linear in (44.6 kg/linear cm)

Operating Temp. Range:
-67 to 185° F (-55 to 85° C)
Cable Construction
Inner Conductor: Solid Ag-plated Cu

Dielectric: Polyethylene

Outer Conductor: GrooveTube® Cu

Standard Finish:
Polyolefin over Sn-plated Cu Braid

(a wide variety of other protective finishes and armors available)

Available Connectors
BNC, F, Type N

(maximum frequency dependent on cable; other connectors available)

Specifications
For attenuation data and additional specifications refer to PDF datasheet.